• IPL-4 Core Isolated Perfused Lung System for Rabbit to Fetal Pig

IPL-4 is an isolated organ perfusion system is specially designed for rabbit or fetal pig lung for measurement of key parameters associated with ex-vivo pulmonary assays.

Please note: For a functional unit, the core system requires the addition of a selection of a cannula set and core system options as well as a ventilator.

IPL-4 Core Isolated Perfused Lung System
  • Deoxygenation Unit for IPL-4 (DEOXY200-4)

For deoxygenation of blood or buffers containing proteins (e.g. albumin) or erythrocytes

Deoxygenation Unit for IPL-4 (DEOXY200-4)
  • Real Time Flow Measurement for IPL-2 or IPL-4

Direct real-time flow measurement with functional IPL-2 or IPL-4 systems

Flow Measurement Options
  • Venous Pressure Measurement for all IPL Systems (VPM)

Venous pressure transducer and amplifier for venous pressure measurement in an isolated perfused lung system. Amplifier module requires suitable PLUGSYS housing.

Venous Pressure Measurement for all IPL Systems (VPM)
  • Addition for Filtration of Recirculated Perfusate for All Isolated Organ Systems

Includes:

  • In-line Holder for disc particle filter, Diameter = 47 mm
  • Polypropylene Particle Filter, 45 µm, Diameter = 47 mm (pack of 100)
Filtration of Recirculated
  • Measurement of pO2, pH, pCO2 for All Isolated Organ Systems

The Universal Perfusion Solution Monitor permits precise continuous or discontinuous measurement in liquid media or perfusate of these three key parameters: pO2, pH and pCO2.

It can be used in any isolated organ system: heart, lung, liver, kidney or other organs. It also can be combined with any self-built perfusion system by adding a suitable PLUGSYS housing for the listed modules.

pO2, pCO2 and pH Measurement
  • Temperature Measurement Addition for All Isolated Organ Systems

Measure perfusate temperature in any isolated perfused organ system in one of two ways:

  • Using the PLUGSYS Thermocouple Amplifier Module for continuous recording of temperature
  • Using a handlheld thermometer showing digital display, no continuous recording possibility
Temperature Measurement
  • Drug Addition Options for All Isolated Organ Systems

These options for drug addition can be added to any isolated organ system where flow is measured or calculated and a drug must be added in a certain ratio.

There are two options: 

  • Perfusion flow-controlled drug addition with syringe pump: allows a drug addition proportional to the measured flow in order to maintain a stable drug concentration at any (constant pressure) flow rate. Requires HSE software to read and calculate the flow to control the syringe pump flow.
  • Perfusion drug addition with syringe pump: allows drug addition at a set flow rate.
Drug Addition